VMware: vSphere HA Agent is in the Network Partitioned State

The vSphere HA agent on a host is in the Network Partitioned state. User intervention might be required to resolve this situation.

Problem:
While the virtual machines running on the host continue to be monitored by the master hosts that are responsible for them, vSphere HA's ability to restart the virtual machines after a failure is affected. First, each master host has access to a subset of the hosts, so less fail-over capacity is available to each host. Second, vSphere HA might be unable to restart a Secondary VM after a failure.

Cause:
A host is reported as partitioned if both of the following conditions are met:
  • The vSphere HA master host to which vCenter Server is connected is unable to communicate with the host by using the management network, but is able to communicate with that host by using the heartbeat datastores that have been selected for it.
  • The host is not isolated.

A network partition can occur for a number of reasons including incorrect VLAN tagging, the failure of a physical NIC or switch, configuring a cluster with some hosts that use only IPv4 and others that use only IPv6, or the management networks for some hosts were moved to a different virtual switch without first putting the host into maintenance mode.

Solution:
Resolve the networking problem that prevents the hosts from communicating by using the management networks.


Reference:
1.  vSphere Troubleshooting

VMware: ESXi Hang / Stuck /Slow during Startup


VMware ESX and VMware ESXi are bare metal embedded hypervisors that are VMware's enterprise software hypervisors for guest virtual servers that run directly on host server hardware without requiring an additional underlying operating system.

The basic server requires some form of persistent storage (typically an array of hard disk drives) that stores the hypervisor and support files. A smaller footprint variant, ESXi, does away with the first requirement by permitting placement of the hypervisor on a dedicated compact storage device. Both variants support the services offered by VMware Infrastructure.

Please note that if you experience an issue (hang / stuck / slow) while restarting your ESXi host(s), this issue is due to USB Arbitrator service which manages USB pass-through. This service does not support simultaneous USB connections both from USB devices and from USB service console.

One of the options to solve this issue is by waiting the host to boot up and disabling USB arbitrator service auto-start on next reboot at the ESXi console:

chkconfig usbarbitrator off

Otherwise, you can reboot the host, actually for me once booted up host it worked fine, so if you need to disable USB arbitrator service without rebooting:

service usbarbitrator stop


References:
1.  VMware vSphere® 5.1 Release Notes

2.  ESXi 5.1: Stuck on running usbarbitrator start

3.  VM ESXI 5.1 hangs when starting vmfs3 loaded successfully

Cisco: UCS C200 and C210 Servers Windows Server 2012 or Windows Server 2008 R2 Installation Fail

Cisco UCS C210 M2 server is a general- purpose, 2-socket, 2 rack unit (RU) rack server that balances performance, density, and efficiency for storage-intensive workloads. The system is built for applications such as network file servers and appliances, storage servers, database servers, and content-delivery servers.

Building on the success of the UCS C-Series servers, the UCS C210 M2 server extends the capabilities of the Cisco Unified Computing System, using Intel's latest Xeon 5600 Series multicore processors to deliver even better performance and efficiency.

Please note that if you have a Cisco UCS C200 or C210 rack-mount server with a Intel Quad port GbE HBA adapter, you must uninstall it before you install Windows 2012 or Windows 2008 R2 on the server. You may reinstall it later, but if the adapter is present during Windows installation, the installation will fail citing an unexpected error.


References:
1.  Cisco UCS C210 M2 General-Purpose Rack Server
http://www.cisco.com/en/US/products/ps10889/index.html

2.  Windows Server 2012 and Windows Server 2008 Installation
http://www.cisco.com/en/US/docs/unified_computing/ucs/os-install-guides/windows/CSERIES-WINDOWS_chapter_011.html

Sunday, 16 June 2013

Veeam: Unable to Migrate vApp Virtual Machines from Instant Recovery to Production

Veeam Backup & Replication provides powerful, easy to use, and affordable data protection for virtualized applications and data on VMware vSphere. It unifies backup and replication in a single solution and its patented vPower technology leverages virtualization to reinvent data protection. There are no agents to manage, no need to babysit backup jobs, and you can verify the recover-ability of every backup, every time.

Instead of making users wait while you provision storage, extract the backup and copy it to production, restart a VM directly from the backup. With Instant VM Recovery, you can recover a failed VM in as little as 2 minutes. Please note that Veeam is unable to migrate vApp virtual machines from Instant VM Recovery to production. (based on practical results)


Reference:
1.  Veeam Backup & Replication for VMware and Hyper-V

Wednesday, 12 June 2013

APC: Switched Rack PDU (Power Distribution Unit)

APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend up-time of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.

Availability:
  • Network management
  • Remote individual outlet control
  • Alarm thresholds
  • Local current monitoring display
  • Power delays
  • Load indicator LED
  • Flash upgradeable
  • Integrates with InfaStruXure central
Agility:
  • Rack-mountable
  • Single input power source
  • Wide range of input and output connections

References:
1.  Switched Rack PDU

2.  APC Rack PDU

IT Technology: Inductive Charging / Wireless Charging / Cordless Charging


Inductive charging (Wireless charging or Cordless charging) uses an electromagnetic field to transfer energy between two objects. This is usually done with a charging station. Energy is sent through an inductive coupling to an electrical device, which can then use that energy to charge batteries or run the device.

Induction chargers typically use an induction coil to create an alternating electromagnetic field from within a charging base station, and a second induction coil in the portable device takes power from the electromagnetic field and converts it back into electrical current to charge the battery. The two induction coils in proximity combine to form an electrical transformer.

Greater distances between sender and receiver coils can be achieved when the inductive charging system uses resonant inductive coupling.


Here are the pros and cons of the inductive charging:

Pros
  • Lower risk of electrical shock or shorting out when wet because there are no exposed conductors, for example toothbrushes and shavers, or outdoors
  • Protected connections - no corrosion when the electronics are all enclosed, away from water or oxygen in the atmosphere
  • Safer for medical implants - for embedded medical devices, allows recharging/powering through the skin rather than having wires penetrate the skin, which would increase the risk of infection
  • Convenience - rather than having to connect a power cable, the device can be placed on or close to a charge plate or stand
  • Easier than plugging into a power cable (important for disabled people)


Cons
  • Lower efficiency, waste heat - The main disadvantages of inductive charging are its lower efficiency and increased resistive heating in comparison to direct contact. Implementations using lower frequencies or older drive technologies charge more slowly and generate heat within most portable electronics
  • More costly - Inductive charging also requires drive electronics and coils in both device and charger, increasing the complexity and cost of manufacturing
  • Slower charging - due to the lower efficiency, devices can take longer to charge when supplied power is equal
  • Inconvenience - When a mobile device is connected to a cable, it can be freely moved around and operated while charging. In some implementations of inductive charging (such as the Qi standard), the mobile device must be left on a pad, and thus can't be moved around or easily operated while charging. In practice, this defeats the point of wireless charging as the convenience factor is removed
  • Incompatibility - Unlike (for example) a standardized MicroUSB charging connector, there are no de facto standards, potentially leaving a consumer, organization or manufacturer with redundant equipment when a standard emerges. (Note: Qi has become a standard adopted by many companies such as Google and Nokia.)

For your information, newer approaches reduce transfer losses through the use of ultra-thin coils, higher frequencies, and optimized drive electronics. These results in more efficient and compact chargers and receivers, facilitating their integration into mobile devices or batteries with minimal changes required. These technologies provide charging times comparable to wired approaches, and they are rapidly finding their way into mobile devices. For example, the Magne Charge vehicle recharger system employs high-frequency induction to deliver high power at an efficiency of 86% (6.6 kW power delivery from a 7.68 kW power draw).


References:
1.  Wireless Charging

2.  2013 Best Wireless Charger Comparisons and Reviews

3.  Energizer Inductive Charger Review

Thursday, 6 June 2013

APC: Automatic Transfer Switches (ATS)


APC Rack Automatic Transfer Switches (rack ATS) provide reliable, redundant power to single-corded equipment. The rack ATS has dual input power cords supplying power to the connected load. If the primary power source becomes unavailable, the rack ATS will seamlessly source power from the secondary source without interrupting critical loads. The Rack ATS has built-in network connectivity, which allows for remote management via Web, SNMP, or Telnet interfaces.


Advantages:
  • Quick Transfer Rate

Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.

  • Wide range of input and output connections

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

  • Remote Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

  • Dual Input Power Sources


Supplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternative power source.



References:
1.  Rack-mount Transfer Switches

2.  APC AP7750 Automatic Transfer Switch Review